Replacing a RAID adapter battery holder

Use this information to install a RAID adapter battery holder.

Before you install a RAID adapter battery holder, complete the following steps:
  1. Read Safety and Installation guidelines.
  2. If the compute node is installed in a NeXtScale n1200 Enclosure, remove it (see Removing a compute node from a chassis for instructions).
  3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you.

To install a RAID adapter battery holder, complete the following steps:

  1. Remove the cover (see Removing the compute node cover).
  2. Align the battery holder hooks and place the battery holder on the air baffle.
    Figure 1. RAID adapter battery holder alignment
    RAID adapter battery holder alignment
  3. Press the latch and push the battery holder forward to the hook.
    Figure 2. RAID adapter battery holder installation
    RAID adapter battery holder installation
  4. Replace the air baffle (see Replacing the air baffle).
  5. Replace the cover (see Installing the compute node cover).
  6. Slide the node into the rack.