80010202-0701ffff : Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

Numeric sensor [NumericSensorElementName] going low (lower critical) has asserted.

This message is for the use case when an implementation has detected a Lower Critical sensor going low has asserted.

May also be shown as 800102020701ffff or 0x800102020701ffff

Severity

Error

Alert Category

Critical - Voltage

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0480

SNMP Trap ID

1

Automatically Notify Support

Yes

User Response

If the specified sensor is CMOS battery, replace the system battery. If the specified sensor is Planar 3.3V or Planar 5V, (trained technician only) replace the system board. If the specified sensor is Planar 12V, complete the following steps until the problem is solved:
  1. Check power supply n LED.
  2. Remove the failing power supply.
  3. Follow actions in "Power Problems and Solving Power Problems".
  4. (Trained technician only) Replace the system board. (n = power supply number)