80010701-1001ffff : Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted. (PCI Riser 1 Temp)

Numeric sensor [NumericSensorElementName] going high (upper non-critical) has asserted. (PCI Riser 1 Temp)

This message is for the use case when an implementation has detected an Upper Non-critical sensor going high has asserted.

May also be shown as 800107011001ffff or 0x800107011001ffff

Severity

Warning

Alert Category

Warning - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0490

SNMP Trap ID

12

Automatically Notify Support

No

User Response

  1. Make sure there is a node filler correctly installed for the empty node slot.
  2. Make sure the air baffles are placed and correctly installed; and make sure the node cover is installed and completely closed.
  3. Make sure the fans are operating, and there are no obstructions to the airflow (both front and rear of the server).
  4. Reduce the Ambient temperature. The system must be operating within the specifications. (see Features and specifications for more information)