Numeric sensor [NumericSensorElementName] going high (upper non-critical) has
asserted. (PCI Riser 2 Temp)
This message is for the use case when an implementation has detected an
Upper Non-critical sensor going high has asserted.
May also be shown as
800107011002ffff or 0x800107011002ffff
Alert Category
Warning - Temperature
CIM Information
Prefix:PLAT
and ID:0490
Automatically Notify Support
No
User Response
- Make sure there is a node filler correctly installed for the empty node slot.
- Make sure the air baffles are placed and correctly installed; and make sure the node cover is installed and completely closed.
- Make sure the fans are operating, and there are no obstructions to the airflow (both front and rear of the server).
- Reduce the Ambient temperature. The system must be operating within the specifications. (see Features and specifications for more information)