The Drive [StorageVolumeElementName] has been disabled due to a detected fault. (1U Storage HDD0)
This message is for the use case when an implementation has detected a
Drive was Disabled due to fault.
May also be shown as
806f010d0405ffff or 0x806f010d0405ffff
Alert Category
Critical - Hard Disk drive
CIM Information
Prefix:PLAT
and ID:0164
Automatically Notify Support
Yes
User Response
- Run the hard disk drive diagnostic test on drive n.
- Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive)
b. Cable from the system board to the backplane
- Replace the following components one at a time, in the order shown, restarting the server each time:
a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)