806f0507-0301ffff : [ProcessorElementName] has a Configuration Mismatch. (CPU 1)

[ProcessorElementName] has a Configuration Mismatch. (CPU 1)

This message is for the use case when an implementation has detected a Processor Configuration Mismatch has occurred.

May also be shown as 806f05070301ffff or 0x806f05070301ffff

Severity

Error

Alert Category

Critical - CPU

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0062

SNMP Trap ID

40

Automatically Notify Support

No

User Response

  1. Check the CPU LED. See more information about the CPU LED in Light path diagnostics.
  2. Check for a server firmware update. Important: Some cluster solutions require specific code levels or coordinated code updates. If the device is part of a cluster solution, verify that the latest level of code is supported for the cluster solution before you update the code.
  3. Make sure that the installed microprocessors are compatible with each other.
  4. (Trained technician only) Reseat microprocessor n.
  5. (Trained technician only) Replace microprocessor n. (n = microprocessor number)