Use this information to solve microprocessor problems.
The microprocessor's
symptoms and actions table with one level of row and column headers.
- Follow the suggested actions in the order in which they are listed
in the Action column until the problem is solved.
- If an action step is preceded by "(Trained technician only)," that step must be performed only by a trained technician.
- Go to the IBM support website at the IBM support portal to check for technical information, hints, tips,
and new device drivers or to submit a request for information.
|
Symptom |
Action |
The server goes directly to the POST Event Viewer
when it is turned on. |
- Correct any errors that are indicated by the light path diagnostics
LEDs (see Light path diagnostics).
- Make sure that the server supports all the microprocessors and
that the microprocessors match in speed and cache size. To view the
microprocessor information, run the Setup utility and select .
- (Trained technician only) Make sure that microprocessor 1 is seated
correctly.
- (Trained technician only) Remove microprocessor 2 and restart
the server.
- Replace the following components one at a time, in the order shown,
restarting the server each time:
- (Trained technician only) Microprocessor
- (Trained technician only) System board
|