Replaceable server components

The replaceable server components for NeXtScale n1200 Enclosure Types 5456.

Replaceable components consist of the following:
  • Structural parts: Purchase and replacement of structural parts (components, such as chassis assembly, top cover, and bezel) is your responsibility. If Lenovo acquires or installs a structural component at your request, you will be charged for the service. See Structural parts for the list of structural parts.
  • Tier 1 customer replaceable unit (CRU): Replacement of Tier 1 CRUs is your responsibility. If Lenovo installs a Tier 1 CRU at your request, you will be charged for the installation.
  • Tier 2 customer replaceable unit: You may install a Tier 2 CRU yourself or request Lenovo to install it, at no additional charge, under the type of warranty service that is designated for your server.
  • Field replaceable units (FRUs): Only Lenovo service technicians are authorized to install or replace FRUs.

For information about the terms of the warranty and getting service and assistance, see the Warranty Information document that comes with the server. For more information about getting service and assistance, see Getting help and technical assistance.

Visit the ServerProven website for the latest options supporting plan.

The following illustration shows the major components in the server. The illustrations in this document might differ slightly from your hardware. For a list of structural parts, see Structural parts.

Figure 1. Server components

The following table lists the part numbers for the server replaceable components.

Table 1. Parts listing, Types 5456.

Four column table documenting the index number, description of server component, CRU part number (Tier 1), and CRU part number (Tier 2).

Index Description CRU part number (Tier 1) CRU part number (Tier 2) FRU part number
1 System Fans 00Y7929    
2 Fan power control 2 (Lenovo version) 01PF064    
2 Fan power control (IBM version) 00KA860    
3 Power supply filler 94Y7610    
4 Power supply, 900 watt, AC 00YJ918 or 00MX927    
4 Power supply, 900 watt, AC 94Y8314    
4 Power supply, 900 watt, CFF -48V DC 94Y8167    
4 Power supply, 1300 watt, AC, Platinum 69Y5925    
4 Power supply, 1300 watt, AC, Platinum 94Y8183, 00YJ924, 01PF547 or 00MX932    
4 Power supply, 1300 watt, AC, Titanium 00Y9107    
4 Power supply, 1300 watt, AC, Titanium 00YJ947 or 01KP987    
4 Power supply, 1300 watt, AC, Titanium 94Y8179    
4 Power supply, 1300 watt, AC, Titanium 00YJ988    
4 Power supply, 1300 watt, AC, Titanium 94Y8277    
4 Power supply, 1500 watt, Platinum 94Y8181, 00YJ920, 01PF549 or 00MX929    
4 Power supply, 2000 watt, Platinum 94Y8207    
4 Power supply, 2000 watt 00YJ989 or 01KP989    
4 Power supply, 1300 watt, AC, Titanium 00YJ900, 01PF519 or 00MX911    
5 Rail kit 88Y6721    
10 Chassis midplane     00YE248
  Fan signal/power cable   00AM348  
  Clamp core 94Y8175    
  T8 torx screwdriver (provided on the back of the chassis) 00FK488    
  Video and USB breakout cable 81Y2889    
  Line cord, 10 amp/125-250VAC- 1M (RoHS) 39M5374    
  PDU jumper cord 39M5392    
  530 MM/10A cord 39M5401    
  Line cord, Y jumper 39M5450    
  Y jumper cord 69Y1627    
  Hypervisor, embedded USB flash device 42D0545    
  Battery, 3.0 volt 33F8354    
  Miscellaneous kit 00AM457 or 02JJ890    
Note: Due to security concern, it is NOT allowed to update FPC (IBM version) to FPC 2 (Lenovo version). With a FPC (IBM version) installed, only do upgrade with IBM firmware or replacement with another unit of IBM FPC. With a FPC 2 (Lenovo version) installed, on the other hand, only do upgrade with Lenovo firmware or replacement with another unit of Lenovo FPC 2. Note that if IBM FPC is plugged in Lenovo chassis, there will be VPD issue (see N1200 fan power controller web shows wrong machine type VPD for more information).