806f020d-0407ffff : Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Computer HDD6)

Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (Computer HDD6)

This message is for the use case when an implementation has detected an Array Failure is Predicted.

May also be shown as 806f020d0407ffff or 0x806f020d0407ffff

Severity

Warning

Alert Category

System - Predicted Failure

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0168

SNMP Trap ID

27

Automatically Notify Support

Yes

User Response

  1. Run the hard disk drive diagnostic test on drive n.
  2. Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
  3. Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)