816f0a13-0301ffff : Bus [SensorElementName] has recovered from a Fatal Bus Error. (CPU 1 PECI)

Bus [SensorElementName] has recovered from a Fatal Bus Error. (CPU 1 PECI)

This message is for the use case when an implementation has detected that a system has recovered from a Bus Fatal Error.

May also be shown as 816f0a130301ffff or 0x816f0a130301ffff

Severity

Info

Alert Category

Critical - Other

Serviceable

No

CIM Information

Prefix:PLAT

and ID:0245

SNMP Trap ID

50

Automatically Notify Support

No

User Response

  1. (Trained technician only) Replace microprocessor n (see Removing a microprocessor and heat sink and Replacing a microprocessor and heat sink).
  2. If the problem persists and there is no other CPU with the same error indication, replace the system board.
  3. (Trained technician only) Replace the system board (see Removing the system board and Replacing the system board). (n = microprocessor number)