Removing a compute node from a chassis

Use this information to remove a compute node from a NeXtScale nx360 M5 compute node.

Before you remove a compute node, complete the following steps:
  1. Read Safety and Installation guidelines.
  2. If the compute node is operating, shut down the operating system.
  3. Press the power button to turn off the compute node (see Turning off the compute node for more information).

To remove the compute node from a chassis, complete the following steps:

  1. Open the front handle as shown in the illustration. The compute node moves out of the node bay approximately 0.6 cm (0.25 inch).
    Figure 1. Removal of a NeXtScale nx360 M5 compute node from a chassis
    Graphic illustrating the removal of a NeXtScale nx360 M5 compute node from a chassis
    Attention:
    • To maintain proper system cooling, do not operate the NeXtScale n1200 Enclosure without a compute node or node bay filler installed in each node bay.
    • When you remove the compute node, note the node bay number. Reinstalling a compute node into a different node bay from the one it was removed from can have unintended consequences. Some configuration information and update options are established according to node bay number. If you reinstall the compute node into a different node bay, you might have to reconfigure the compute node.
  2. Pull the compute node out of the node bay.
  3. Install either a node bay filler or another compute node in the node bay within 1 minute.

If you are instructed to return the compute node, follow all packaging instructions, and use any packaging materials for shipping that are supplied to you.