Use this information to update the DMI/SMBIOS data.
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model> [access_method]
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> [access_method]
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag> [access_method]
mtm xxxxyyy
, where xxxx is
the machine type and yyy is the server model number.sn zzzzzzz
, where zzzzzzz is the serial
number.asset aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa
,
where aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa is the asset tag number.Online authenticated LAN access, type the command:
[host <imm_internal_ip>]
[user <imm_user_id>][password <imm_password>]
account
(1
of 12 accounts). The default value is USERID.The following commands are examples of using the userid and password default values and not using the default values:
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
--user <imm_user_id> --password <imm_password>
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> --user <imm_user_id>
--password <imm_password>
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
--user <imm_user_id> --password <imm_password>
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
You do not need to specify a value for access_method when you use this access method.
The KCS access method uses the IPMI/KCS interface. This method requires that the IPMI driver be installed. Some operating systems have the IPMI driver installed by default. ASU provides the corresponding mapping layer. To download the Advanced Settings Utility Users Guide, complete the following steps:
The following commands are examples of using the userid and password default values and not using the default values:
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model>
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n>
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag>
Bootable media: Remote LAN access, type the command:
host <imm_external_ip>
[user <imm_user_id>][password <imm_password>]
account
(1
of 12 accounts). The default value is USERID.The following commands are examples of using the userid and password default values and not using the default values:
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model> --host <imm_ip>
--user <imm_user_id> --password <imm_password>
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> --host <imm_ip>
--user <imm_user_id> --password <imm_password>
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag> --host <imm_ip>
--user <imm_user_id> --password <imm_password>
asu set SYSTEM_PROD_DATA.SysInfoProdName <m/t_model> --host <imm_ip>
asu set SYSTEM_PROD_DATA.SysInfoSerialNum <s/n> --host <imm_ip>
asu set SYSTEM_PROD_DATA.SysEncloseAssetTag <asset_tag> --host <imm_ip>
Bootable media:
You can also build a bootable media using the applications available through the ToolsCenter website at the Lenovo ToolsCenter website. From the Lenovo ToolsCenter page, scroll down for the available tools.