Numeric sensor [NumericSensorElementName] going low (lower critical) has
asserted. (CMOS Battery)
This message is for the use case when an implementation has detected a
Lower Critical sensor going low has asserted.
May also be shown as
800102020701ffff or 0x800102020701ffff
Alert Category
Critical - Voltage
CIM Information
Prefix:PLAT
and ID:0480
Automatically Notify Support
Yes
User Response
If the specified sensor is CMOS battery, replace the system battery.
If the specified sensor is Planar 3.3V or Planar 5V, (trained technician only) replace the system board.
If the specified sensor is Planar 12V, complete the following steps until the problem is solved:
- Check power supply n LED.
- Remove the failing power supply.
- Follow actions in "Power Problems and Solving Power Problems".
- (Trained technician only) Replace the system board. (n = power supply number)
SysBrd 12V :
SysBrd 3.3V :
SysBrd 5V :