Numeric sensor [NumericSensorElementName] going high (upper non-recoverable)
has asserted. (GPU Outlet Temp)
This message is for the use case when an implementation has detected an
Upper Non-recoverable sensor going high has
asserted.
May also be shown as
80010b013706ffff or 0x80010b013706ffff
Alert Category
Critical - Temperature
CIM Information
Prefix:PLAT
and ID:0498
Automatically Notify Support
No
User Response
- Make sure that the water loop is operating, the relevant water tubes are in place and correctly installed, and that the server cover is installed and completely closed.
- Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
- Make sure that the heat sink for microprocessor n.
- (Trained technician only) Replace system board.