80010b01-3707ffff : Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted. (HDD Outlet Temp)

Numeric sensor [NumericSensorElementName] going high (upper non-recoverable) has asserted. (HDD Outlet Temp)

This message is for the use case when an implementation has detected an Upper Non-recoverable sensor going high has asserted.

May also be shown as 80010b013707ffff or 0x80010b013707ffff

Severity

Error

Alert Category

Critical - Temperature

Serviceable

Yes

CIM Information

Prefix:PLAT

and ID:0498

SNMP Trap ID

0

Automatically Notify Support

No

User Response

  1. Make sure that the water loop is operating, the relevant water tubes are in place and correctly installed, and that the server cover is installed and completely closed.
  2. Check the ambient temperature. You must be operating within the specifications (see Server Features and specifications for more information).
  3. Make sure that the heat sink for microprocessor n.
  4. (Trained technician only) Replace system board.