Failure Predicted on [StorageVolumeElementName] for array [ComputerSystemElementName]. (SDHV Drive 11)
This message is for the use case when an implementation has detected an
Array Failure is Predicted.
May also be shown as
806f020d041affff or 0x806f020d041affff
Alert Category
System - Predicted Failure
CIM Information
Prefix:PLAT
and ID:0168
Automatically Notify Support
Yes
User Response
- Run the hard disk drive diagnostic test on drive n.
- Reseat the following components: a. Hard disk drive (wait 1 minute or more before reinstalling the drive) b. Cable from the system board to the backplane
- Replace the following components one at a time, in the order shown, restarting the server each time: a. Hard disk drive b. Cable from the system board to the backplane c. Hard disk drive backplane (n = hard disk drive number)