(Trained service technician only) Use these instructions
to remove the chassis midplane from the NeXtScale n1200 Enclosure.
Before you remove the chassis midplane, complete the following
steps:
- Read Safety and Installation guidelines
- Record the machine type model, the chassis serial number, and
retrieve the existing universally unique identifier (UUID) information
from the chassis midplane that you are removing. The procedure for
obtaining this data might require different steps depending on the
functional state of the chassis.
- Chassis is operating:
- Log onto the IMM2 and access the command-line interface (CLI).
You can access the IMM2 CLI through a direct serial or Ethernet connection
to the IMM2, through a Telnet connection to the IP address of the
IMM2, or through a Secure Shell (SSH) connection to the IMM2. You
must authenticate with the IMM2 before issuing commands.
- Query for the machine type model, chassis serial number, and the
UUID values by using the CLI info command. Record this information
before you proceed.
- Chassis is not operating:
- Obtain the chassis serial number and the machine type model from
one of the chassis labels. Use this information to query the PSG Entitlement Warehouse for the UUID.
- Record the chassis serial number, the machine type model, and
the UUID before you proceed.
- Shut down the operating systems and turn off any compute nodes in
the chassis. See the documentation that comes with the compute node
for detailed instructions.
- Open the release handles on the compute nodes and
the management node, if one is installed, to disengage the nodes from
the chassis midplane connectors.
- Disconnect the chassis from power.
- Disconnect all cables from the modules in the rear of the chassis.
- Remove the components from rear and front of the chassis.
To remove the chassis midplane, complete the following
steps.
- Remove the compute nodes in the front of the chassis.
- Remove all EMC shields on both sides.
Figure 1. Upper EMC shields removal
Figure 2. Lower EMC shields removal
- Remove manifold retention brackets that are retaining manifolds
(top enclosure position only).
Figure 3. Retention bracket removal
- Push the latch up upwards and slide the drip sensor assembly
backwards, then; lift the drip sensor assembly up to clear sensor
post and pull it out of the enclosure.
Figure 4. Drip sensor assembly removal
- Remove FPC card module and FPC card module support bracket.
Figure 5. FPC card module removal
Figure 6. Support bracket removal
- Remove the blank filler.
Figure 7. Blank filler removal
- Remove all power supplies from the enclosure.
Figure 8. Hot-swap power supply removal
- Remove eight screws (using the screwdriver contained in
the manifold repair kit) to loosen two manifolds from the enclosure.
Figure 9. Manifold screw locations
Table 1. Manifold screw locations
1 Screws |
2 Manifold |
- Remove eight screws to remove two support brackets on both
sides.
Figure 10. Support bracket removal
- Remove two EIA covers at the front of the enclosure, then,
remove eight screws.
Figure 11. EIA cover removal
- Slide the enclosure out of the rack.
Figure 12. Sliding the enclosure
- Loosen the three captive screws on the top cover.
- Rotate the top cover outwards.
Figure 13. Top cover outward rotation
- Loosen the three captive screws that secure the chassis
midplane to the chassis.
- Lift up the chassis midplane half way. Put a screwdriver
or a stick in the middle of the chassis midplane so your hands are
free.
Figure 14. Removal of the chassis midplane from a chassis
- Unplug the two fan cables on chassis midplane
- Carefully grasp the chassis midplane and slide it away
from the chassis.
Note: Make sure that you do not grasp the connectors on the
chassis midplane. You could damage the connectors.
Figure 15. Removal of the chassis midplane from a chassis