Removing the battery from the fan power control

Use this information to remove the CMOS battery from an fan power control.

The following notes describe information that you must consider when replacing the battery.

To remove the battery, complete the following steps:

  1. Read the safety information that begins on Safety and Installation guidelines.
  2. If the fan power control is installed in the NeXtScale n1200 Enclosure, remove it (see Removing the fan power control).
  3. Carefully lay the fan power control on a flat, static-protective surface.
  4. Locate the battery.
    Figure 1. Locate the battery
    Locate the battery
  5. Using your fingernail, press the battery retaining clip. The battery should pop free.
    Figure 2. Battery removal
    Battery removal
    Attention: Do not lift the battery by using excessive force. Failing to remove the battery properly may damage the socket on the fan power control. Any damage to the socket may require replacing the fan power control.
  6. Lift the battery from the socket.
  7. Dispose of the battery as required by local ordinances or regulations. See the Environmental Notices and User's Guide on the Documentation CD for more information.