Use these instructions to install an fan power control in the NeXtScale n1200 Enclosure. You can install an fan power control while the NeXtScale n1200 Enclosure is powered on.
To install an fan power control,
complete the following steps.
Figure 1. Installation
of an fan power control into
the chassis
- Open the release handle on the fan power control (rotate
the handle down).
- Align the fan power control with
the bay on the chassis and slide the module into the module bay until
it is seated.
- Close the release handles (rotate the handle up).
After you install the
fan power control, complete the following steps.
- Connect all cables to the module.
- If you want to restore the old chassis settings and chassis midplane
VPD onto the new fan power control after it is replaced, make sure you have followed the
restore procedures to restore all of the chassis settings and chassis
midplane VPD data from the USB key which is taken from the old fan power control:
- Update the server firmware to the latest level (see Configuration options).
- Log in to the web interface (see Using the web interface).
- Go to System Information section, click on the Midplane
VPD tab.
- For chassis midplane VPD backup, restoring, and updating, see System information options.