Replacing a memory module

Use this information to install a DIMM.

Before you install a dual inline memory module (DIMM), complete the following steps:
  1. Read Safety and Installation guidelines.
  2. If the compute node is installed in a NeXtScale n1200 Enclosure, remove it (see Removing a compute node from a chassis for instructions).
  3. Carefully lay the compute node on a flat, static-protective surface, orienting the compute node with the bezel pointing toward you.
  1. Remove the cover (see Removing the compute node cover).
  2. Remove the air baffle (see Removing the air baffle).
  3. Carefully open the retaining clips on each end of the DIMM connector and remove the DIMM.
    Attention: To avoid breaking the retaining clips or damaging the DIMM connectors, open and close the clips gently.
    Figure 1. DIMM installation
    DIMM removal
  4. Touch the static-protective package that contains the DIMM to any unpainted metal surface on the outside of the server. Then, remove the DIMM from the package.
  5. Turn the DIMM so that the alignment slot align correctly with the alignment tab.
  6. Insert the DIMM into the connector by aligning the edges of the DIMM with the slots at the ends of the DIMM connector.
  7. Firmly press the DIMM straight down into the connector by applying pressure on both ends of the DIMM simultaneously. The retaining clips snap into the locked position when the DIMM is firmly seated in the connector.
    Note: If there is a gap between the DIMM and the retaining clips, the DIMM has not been correctly inserted; open the retaining clips, remove the DIMM, and then reinsert it.
  8. Replace the air baffle (see Replacing the air baffle).
    Note: Close all the retaining clips even for slots without DIMMs installed before replacing the air baffle.
  9. Replace the cover (see Installing the compute node cover).
  10. Reconnect the power cords and any cables that you removed.
  11. Turn on the peripheral devices and the server.